Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Contact Us
rdearmas

rdearmas

rdearmas@adrmg.com

0

Article
Last Month

rdearmas articles

All Categories
  • All Categories
  • Prices/Polices
  • Installation Manuals
  • Brochures / Literature
  • Log Set Compositions
  • Bromic Patio Heaters
  • Solaire Infrared Grills
  • Vented Gas Logs
  • Chillbuster Vent-Free Gas Logs
  • Alterna (FireBalls, FireStones, FireGlitter)
  • Electronic Ignition Systems
  • FirePits
  • Regulatory Issues
  • Google SketchUp Models
  • Testimonials
  • Featured Articles

Can I use a Corston switch with a Bromic heater or Affinity controller?

Published October 14th, 2026 by rdearmas

Corston control compatibility depends on the switching method: Corston cannot integrate with the Bromic Affinity controller, because the required 0–10V control capability is not available in the Corston product reviewed. A Corston double-pole wall on/off switch might directly switch a Bromic heater if a correctly rated 240V model exists, but it woul

1 min

What should I do if the valve motor drive appears stuck?

Published October 14th, 2026 by rdearmas

On some Rasmussen motorized-valve remote systems, troubleshooting can start with these steps: Replace the four AA receiver batteries. If the motor operates but the valve does not respond, the valve plunger may be sticking. The motor drive can be removed at the wrench flats, the plunger tip wiped clean, and the motor drive reinstalled. Do not overtig

1 min

Do Rasmussen burners need to be derated at higher elevations?

Published October 14th, 2026 by rdearmas

Rasmussen pan burners generally do not require altitude derating. A Rasmussen vent-free set has operated at approximately 8,100 feet without an orifice change or observed performance loss. Because code, listing, installation, and gas-supply requirements may vary by product and location, current product instructions and local requirements should gove

1 min

Do Bromic gas heaters need a high-altitude kit?

Published October 14th, 2026 by rdearmas

Generally, no. A separate high-altitude kit has not been required for Bromic gas heaters, including installations at around 4,300 feet. Similar infrared burner technology has operated successfully at substantially higher elevations without observed performance loss. Always check the current Bromic installation instructions and local gas-code require

1 min

Why can a burner have adequate gas pressure but still be underfired?

Published October 14th, 2026 by rdearmas

A burner can show adequate static pressure and still be underfired if the gas-supply path cannot deliver the required volume at the burner’s rated input. For example, in one CS48 installation, a 1/2-inch gas line at 7 inches water column had roughly 120,000 BTU/hour of capacity, while the CS48 is rated at 175,000 BTU/hour. Increasing the measured pr

1 min

Can I change my installed control system to add variable flame-height control?

Published October 14th, 2026 by rdearmas

Not necessarily. On FireBall installations, changing from one certified control configuration to another has required replacing the complete burner/chassis/control assembly. Field modification is not permitted because the different control systems use different bracketing and the assembly is certification-controlled. Before planning a control upgrad

1 min

Where should the fireplace gas shutoff valve be installed?

Published October 14th, 2026 by rdearmas

Applicable codes commonly require the log-lighter/fireplace gas shutoff valve to be located outside the firebox but within reach. An additional valve may sometimes be installed inside the fireplace for convenience, but an inside-only shutoff can create a safety problem if a fire or leak makes the firebox inaccessible. Installation must comply with c

1 min

What fuel types do Rasmussen gas logs use, and will they work during a power outage?

Published October 14th, 2026 by rdearmas

Rasmussen gas log sets use either Natural Gas or Propane. Rasmussen does not manufacture electric log sets. Depending on the system, most Rasmussen lighting/control systems either run on batteries or require no electrical power. This can allow most gas log configurations to operate during a power outage.

1 min

Why does my sand-pan burner sometimes smell like gas after shutdown?

Published October 14th, 2026 by rdearmas

A brief lingering gas odor can occur after a sand-pan burner is turned off because a small amount of gas can remain in the sand after gas flow stops. Without normal gas-flow pressure, that residual gas may not reach the surface to burn off immediately. The fireplace damper should remain fully open for a vented installation. If the gas odor persists

1 min

What sand should I use in a Rasmussen sand-pan burner?

Published October 14th, 2026 by rdearmas

Use the sand specified and supplied by Rasmussen as the functional burner fill. Rasmussen has used a particular grade of sand in its pan-type burners since the design was introduced. Decorative sand that has not been verified by Rasmussen should not replace the functional Rasmussen burner sand. If a project calls for a different decorative appearanc

1 min

Why does the burner in my Solaire portable grill not stay secured?

Published October 14th, 2026 by rdearmas

Check the bracket at the bottom of the portable grill firebox. If that bracket is bent, the tube on the bottom of the burner may not engage securely. Remove the burner and inspect the firebox bracket before assuming that the burner itself is defective.

1 min

Do Bromic outdoor radiant gas heaters use thermostats?

Published October 14th, 2026 by rdearmas

No. Thermostats are generally associated with heating enclosed spaces, where room-air temperature is the control objective. Bromic outdoor gas patio heaters are radiant heaters intended for unconfined outdoor spaces. They primarily heat people and surfaces rather than controlling air temperature. Thermostats are not offered or recommended by Bromic

1 min

Where should I place a thermometer when using the Solaire rotisserie?

Published October 14th, 2026 by rdearmas

For a Solaire grill without a rear infrared rotisserie burner, the thermometer can be positioned on the rear ledge where the grill configuration provides sufficient space. See the current Great Grilling Simplified guide for the illustrated placement.

1 min
Load More
@ 2026 RASMUSSEN GAS LOGS, RASMUSSEN THE GAS LOG COMPANY, CHILLBUSTER, ALTERNA, FIREGLITTER, SOLAIRE and INFRAVECTION are registered trademarks of Rasmussen Iron Works, Inc. FIREBALLS, FIRESHAPES, FIRESTONES, FIREDROPS and VALVE VANISHER are trademarks of Rasmussen Iron Works, Inc. All rights reserved