Top Two Issues with Electronic Ignitions Systems (EIS)

Written by Rett Rasmussen

Updated at July 27th, 2024

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Prices/Polices
    Logs/Alterna/Chillbuster Prices Solaire Prices Bromic Heater Prices/Programs Logs/Alterna/Chillbuster Policies/Programs Solaire Policies/Programs Forms/Policies Applicable to All Lines
  • Installation Manuals
    Bromic Heaters Vented Gas Logs / Alterna Vent-Free Gas Logs / Alterna Standing Pilot Lighting Controls Solaire Grills EIS Lighting Controls Solaire Portable Grills Log Stacking Instructions FireBalls Stacking Drawings
  • Brochures / Literature
  • Log Set Compositions
    Vented Log Set Compositions Chillbuster Vent-Free Log Set Compositions Rumford Log Set Compositions Accessory Compositions FirePit Log Set Compositions
  • Bromic Patio Heaters
    Troubleshooting - Gas Heaters Troubleshooting - Electric Heaters Troubleshooting - Remote Controllers Unboxing Guides
  • Solaire Infrared Grills
    Solaire Training Solaire Portable Infrared Grills Solaire 27XL Solaire 42 Solaire Side Burners Solaire Island Accessories Solaire Accessories Solaire 21 Solaire 36 Recipes Testimonials Solaire 27 Solaire 30 Solaire 56 Solaire Accent Solaire Demo Program Solaire Warranty Solaire 21XL Solaire 56T Unboxing - What's Inside Solaire "How To" Videos
  • Vented Gas Logs
    Troubleshooting Burners Dimensions - Valve Vanisher - VEI VRP VMV VSP Vented Burners Vented Lighting Controls Rumford Fireplaces
  • Chillbuster Vent-Free Gas Logs
    Burners Lighting Controls Troubleshooting
  • Alterna (FireBalls, FireStones, FireGlitter)
    Vented Vent-Free
  • Electronic Ignition Systems
    Valve Vanisher (VEI) Chillbuster/Alterna VF (EI) RS150 & RL150 24Volt (EIS-N200, etc) Chillbuster (EI)
  • FirePits
  • Regulatory Issues
    DOE
  • Google SketchUp Models
  • Testimonials
  • Featured Articles
+ More
  • Prices/Polices

    • Installation Manuals

      • Brochures / Literature

        • Log Set Compositions

          • Bromic Patio Heaters

            • Solaire Infrared Grills

              • Vented Gas Logs

                • Chillbuster Vent-Free Gas Logs

                  • Alterna (FireBalls, FireStones, FireGlitter)

                    • Electronic Ignition Systems

                      • FirePits

                        • Regulatory Issues

                          • Google SketchUp Models

                            • Testimonials

                              • Featured Articles

                                Electronic Ignition Systems (EIS), also know as Intermittent Pilot Ignition Systems (IPI), are becoming ever more popular, for a variety of reasons. In some cases, it is because of mandates to not install standing pilot systems (usually in new construction installations). In others, consumers feel they are saving resources (both gas and money) by not having a constantly burning pilot (the payback from gas savings versus the cost of the EIS could be as much as twenty years). Another reason is characterized as that of safety, although it is really borne from the consumer’s inherent fear of gas, so they wish to have no open flames at all, no matter how small, when an appliance is unattended.

                                But regardless of the reason, the function of EIS/IPI systems is the same, and the service issues from which we receive calls mostly fall into two categories:

                                1. Ground not established; and
                                2. Sensor is not engulfed by pilot flame during operation.
                                  1. Ground. The EIS system should be viewed as a circuit through which electricity flows. Starting at the control module, this is the path:
                                    Control Module → Orange Electrode Wire → Electrode → Pilot Flame (yes, electricity flows through fire) → Pilot Hood → Pilot Bracket → Gas Log Burner → ** Ground ** → Control Valve → Wiring Harness → back to Control Module.
                                    I’ll address the Pilot Flame in the next section. Establishing Ground can be as easy as scratching off some paint on the burner so that you have metal-to-metal contact between the pilot bracket and the gas log burner. It may be that you need to run a grounding wire from the pilot bracket to a source of ground, such as a gas line, or back to the control valve. Sometimes it’s a matter of trial and error. But regardless of how you achieve it, you must have good ground to complete the circuit.
                                  2. Sensor Must be in the Pilot Flame. The EIS/IPI systems are what I term “Pilot on Demand” systems. When you flip the switch, it starts a lighting sequence, with continuous sparking that lights the pilot gas. The resulting flame must engulf the sensor electrode so that:
                                    1. It competes the circuit (see above); and
                                    2. It “justifies” the pilot flame to the control module. When the pilot flame fully engulfs the electrode, it is essentially telling the control module that “Hey, we’ve got a flame that can light the main burner, so it’s okay to open the valve and let the gas flow to the main burner.”

                                If the pilot flame does not fully engulf the electrode, the control module will just keep on sparking, until it gets tired or finds the flame.

                                Proper positioning of EIS electrode in pilot flame. Note the cherry red color of the electrode tip.

                                If the EIS successfully completes the lighting sequence and lets gas flow to the main burner, but then later the main flame goes out, it is because the pilot flame pulled away from the electrode. Causes of this could be:

                                1. Electrode just barely in adjustment at the edge of the pilot flame.
                                2. The pilot flame is influencing the pilot flame, pulling it away from the electrode.
                                3. Natural draw of the fireplace is pulling the pilot flame off of the electrode.
                                4. Wind has blown the pilot flame away from the electrode.
                                  In the first case, the electrode needs to be adjusted so that it is fully engulfed in the pilot flame from the start. In the other cases, you may need to reposition the pilot and/or provide external shielding to remove flame or wind influence. In any case, the pilot must always fully engulf the electrode in order to provide smooth, continuous operation.

                                If the main burner flame cycles on and off repeatedly, it is due to the flame touching, then pulling away from the electrode.

                                Touch, then pull away; touch, then pull away. Correcting this situation is identical to the above paragraph. You must counteract the influences on the pilot flame so that it stays rock steady on the electrode.

                                The above situations reflect almost 99% of all service calls for EIS/IPI systems. Knowing what causes them is half the battle.  Establishing Ground, setting up the electrode in the correct position during the installation and making the proper adjustments and/or shielding makes up the last half.  And when one “fix” doesn’t correct the problem, try another, because “it ain’t over ’til it’s over.”

                                NOTE:  The EIS-RS150 and EIS-RL150 systems have two electrodes: one for the spark, one for the sensor.  All of the above also applies to the sensor electrode for these systems.

                                ignition problems eis failure

                                Was this article helpful?

                                Yes
                                No
                                Give feedback about this article

                                Featured articles

                                1. 2025 MSRP Price List for Rasmussen Gas Logs, Alterna Contemporary Gas Fires and Chillbuster Vent-free log sets. Effective Date = September 5, 2023
                                2. 2025 Solaire Retail Price List, PDF and XLS format, effective March 20, 2023
                                3. 2024-2025 Bromic MSRP Price List effective October 18, 2024
                                4. How to light the pilot on your gas log set - general instructions
                                5. #1 Vent-Free Issue - Nuisance Shutdown (or difficulty lighting) ODS Pilot
                                6. I can't find replacement parts for my Rasmussen Gas Log, Solaire Grill or Bromic Heater - what should I do?
                                7. General FirePit Guidance
                                8. Solaire Ignition Systems Replacement Parts Matrix and List
                                9. If my infrared burner pops, what can I do?

                                Popular Articles

                                1. 2025 MSRP Price List for Rasmussen Gas Logs, Alterna Contemporary Gas Fires and Chillbuster Vent-free log sets. Effective Date = September 5, 2023
                                2. How to light the pilot on your gas log set - general instructions
                                3. Adding Logs to a Vented Gas Log Set
                                4. 2025 Solaire Retail Price List, PDF and XLS format, effective March 20, 2023
                                5. Rasmussen Vented Gas Logs Brochure
                                6. Alterna Vent-free (FireBalls, FireShapes, FireStones) Instruction Manual
                                7. Platinum Gas shuts down after a short time
                                8. Identification of Burner Features to Clean - Vent-Free Gas Log Sets
                                9. #1 Vent-Free Issue - Nuisance Shutdown (or difficulty lighting) ODS Pilot

                                Related Articles

                                • EIS-RS150 and EIS-RL150 Installation / Operation Manual (Pre 6/2012 model)
                                • I can't find replacement parts for my Rasmussen Gas Log or Solaire Grill, what should I do?
                                • Information on Electronic Ignition Systems, items # EIS-N135, EIS-N200, EIS-350, EIS-N720, EIS-P200, EIS-P350
                                • BTU Capacity for EIS-RS150 and EIS-RL150
                                @ 2024 RASMUSSEN GAS LOGS, RASMUSSEN THE GAS LOG COMPANY, CHILLBUSTER, ALTERNA, FIREGLITTER, SOLAIRE and INFRAVECTION are registered trademarks of Rasmussen Iron Works, Inc. FIREBALLS, FIRESHAPES, FIRESTONES, FIREDROPS and VALVE VANISHER are trademarks of Rasmussen Iron Works, Inc. All rights reserved