How to light the pilot on your gas log set - general instructions
- Prices/Polices
- Installation Manuals
- Brochures / Literature
- Log Set Compositions
- Bromic Patio Heaters
-
Solaire Infrared Grills
Solaire Training Solaire Portable Infrared Grills Solaire 27XL Solaire 42 Solaire Side Burners Solaire Island Accessories Solaire Accessories Solaire 21 Solaire 36 Recipes Testimonials Solaire 27 Solaire 30 Solaire 56 Solaire Accent Solaire Demo Program Solaire Warranty Solaire 21XL Solaire 56T Unboxing - What's Inside Solaire "How To" Videos
- Vented Gas Logs
- Chillbuster Vent-Free Gas Logs
- Alterna (FireBalls, FireStones, FireGlitter)
- Electronic Ignition Systems
- FirePits
- Regulatory Issues
- Google SketchUp Models
- Testimonials
- Featured Articles
-
Prices/Polices
-
Installation Manuals
-
Brochures / Literature
-
Log Set Compositions
-
Bromic Patio Heaters
-
Solaire Infrared Grills
-
Vented Gas Logs
-
Chillbuster Vent-Free Gas Logs
-
Alterna (FireBalls, FireStones, FireGlitter)
-
Electronic Ignition Systems
-
FirePits
-
Regulatory Issues
-
Google SketchUp Models
-
Testimonials
-
Featured Articles
Pilot lighting instructions are in your installation instructions that came with the lighting control. They can also be downloaded from www.RasBox.com, specifically at
http://rasmussen.host4kb.com/category/51/0/10/Installation-Manuals/
In a nutshell:
- Ensure the gas is turned on to allow gas to the fireplace.
- If the log set has a switch on it, place it in the OFF position.
- Turn the safety control valve knob to the PILOT position. At the PILOT position you will be able to push the knob the maximum amount toward the valve.
- Push and hold the knob in for a time sufficient to replace the air in the pilot line with gas (this can sometimes take up to three minutes, as the pilot line is very small, as is the amount of gas flowing to the pilot).
- While pushing the knob in, light the pilot with a match or aim-n-flame (or push the button of the piezo ignitor, if equipped). Continue to hold in the knob with the pilot lit for 30 to 90 seconds, or until such time as when you release the knob, the pilot remains lit.
- Once the pilot remains lit, you must turn the valve to anyplace up to and including full ON to allow gas to flow to the main burner. If the knob remains at PILOT, no gas will flow to the burner.
If you have a remote control, ensure that the batteries are fresh in both the hand-held transmitter and the receiver that is usually located in the fireplace.
Featured articles
- 2024 MSRP Price List for Rasmussen Gas Logs, Alterna Contemporary Gas Fires and Chillbuster Vent-free log sets. Effective September 5, 2023
- 2024 Solaire Retail Price List, PDF and XLS format, effective March 20, 2023
- 2024-2025 Bromic MSRP Price List effective October 18, 2024
- How to light the pilot on your gas log set - general instructions
- #1 Vent-Free Issue - Nuisance Shutdown (or difficulty lighting) ODS Pilot
- I can't find replacement parts for my Rasmussen Gas Log, Solaire Grill or Bromic Heater - what should I do?
- General FirePit Guidance
- Solaire Ignition Systems Replacement Parts Matrix and List
- If my infrared burner pops, what can I do?
Popular Articles
- 2024 MSRP Price List for Rasmussen Gas Logs, Alterna Contemporary Gas Fires and Chillbuster Vent-free log sets. Effective September 5, 2023
- How to light the pilot on your gas log set - general instructions
- 2024 Solaire Retail Price List, PDF and XLS format, effective March 20, 2023
- Adding Logs to a Vented Gas Log Set
- Rasmussen Vented Gas Logs Brochure
- Alterna Vent-free (FireBalls, FireShapes, FireStones) Instruction Manual
- Platinum Gas shuts down after a short time
- #1 Vent-Free Issue - Nuisance Shutdown (or difficulty lighting) ODS Pilot
- I can't find replacement parts for my Rasmussen Gas Log, Solaire Grill or Bromic Heater - what should I do?