Millivolt Vent-Free Burner Shuts Down (But Pilot Flame Still On)
- Prices/Polices
- Installation Manuals
- Brochures / Literature
- Log Set Compositions
- Bromic Patio Heaters
-
Solaire Infrared Grills
Solaire Training Solaire Portable Infrared Grills Solaire 27XL Solaire 42 Solaire Side Burners Solaire Island Accessories Solaire Accessories Solaire 21 Solaire 36 Recipes Testimonials Solaire 27 Solaire 30 Solaire 56 Solaire Accent Solaire Demo Program Solaire Warranty Solaire 21XL Solaire 56T Unboxing - What's Inside Solaire "How To" Videos
- Vented Gas Logs
- Chillbuster Vent-Free Gas Logs
- Alterna (FireBalls, FireStones, FireGlitter)
- Electronic Ignition Systems
- FirePits
- Regulatory Issues
- Google SketchUp Models
- Testimonials
- Featured Articles
-
Prices/Polices
-
Installation Manuals
-
Brochures / Literature
-
Log Set Compositions
-
Bromic Patio Heaters
-
Solaire Infrared Grills
-
Vented Gas Logs
-
Chillbuster Vent-Free Gas Logs
-
Alterna (FireBalls, FireStones, FireGlitter)
-
Electronic Ignition Systems
-
FirePits
-
Regulatory Issues
-
Google SketchUp Models
-
Testimonials
-
Featured Articles
Q - Millivolt Vent-Free Burner Shuts Down, But Pilot Flame Continues To Burn.
A- It may be that the Thermopile, which is the larger of the two elements on the ODS. The smaller, quick-acting thermocouple is the safety feature - it shuts the entire unit down, including the pilot, when the pilot flame becomes unstable or goes out. The Thermopile provides the power to open and close the valve. What you describe can be caused by two possibilities:
- Not enough of the flame is striking it, so it is not generating enough energy. Cleaning the air intake holes may improve this (see article). The next step to take is to ensure that the Thermopile is located as far into the pilot flame as possible. Please note in the below photo the Gap between the Thermopile and where the flame comes out of the assembly.
To improve the performance of the Thermopile, place the blade of a slot-screwdriver beneath the back edge of the Thermopile and rotate the blade clockwise, so that the front tip of the Thermopile mover further into the flame and the Thermopile touches the portion of the ODS from which the flame comes out.
If #1 does not correct the issue, then: - The Thermopile has worn out and no longer creates enough energy to OPEN and CLOSE the valve. Replace the ODS-ROP (we only replace the entire ODS assembly, not the individual components, for safety reasons).
Featured articles
- 2024 MSRP Price List for Rasmussen Gas Logs, Alterna Contemporary Gas Fires and Chillbuster Vent-free log sets. Effective September 5, 2023
- 2024 Solaire Retail Price List, PDF and XLS format, effective March 20, 2023
- 2024-2025 Bromic MSRP Price List effective October 18, 2024
- How to light the pilot on your gas log set - general instructions
- #1 Vent-Free Issue - Nuisance Shutdown (or difficulty lighting) ODS Pilot
- I can't find replacement parts for my Rasmussen Gas Log, Solaire Grill or Bromic Heater - what should I do?
- General FirePit Guidance
- Solaire Ignition Systems Replacement Parts Matrix and List
- If my infrared burner pops, what can I do?
Popular Articles
- 2024 MSRP Price List for Rasmussen Gas Logs, Alterna Contemporary Gas Fires and Chillbuster Vent-free log sets. Effective September 5, 2023
- How to light the pilot on your gas log set - general instructions
- 2024 Solaire Retail Price List, PDF and XLS format, effective March 20, 2023
- Adding Logs to a Vented Gas Log Set
- Alterna Vent-free (FireBalls, FireShapes, FireStones) Instruction Manual
- Rasmussen Vented Gas Logs Brochure
- Platinum Gas shuts down after a short time
- I can't find replacement parts for my Rasmussen Gas Log, Solaire Grill or Bromic Heater - what should I do?
- Flaming Ember Vented Burner and Double Face Addendum Instruction Manuals